Nexodose Dose Monitor
- Client
- Department of Veterans Affairs
- Solicitation No.
- —
- Posted
- 10/19/2026
- Category
- US Federal
- Budget
- —
- NAICS
- 541519
- Set-aside
- Small Businesses (SDVOSB) and Veteran Owned Small Businesses (VOSB) shall be verified in SBA at Small Business Search .Point of Contact for this Sources Sought is:[email? redacted]Department of Veterans AffairsNetwork Contracting Office -153450 S. 4th St
- Contact
- Betty Flores
Description
AI GeneratedThe Department of Veterans Affairs is conducting market research through a Sources Sought announcement to identify qualified businesses capable of providing DoseMonitor/Nexodose Management for Kansas and Missouri VA Medical Facilities. The scope requires annual software maintenance, technical support, updates, license renewals, and the one-time installation and configuration of bi-directional HL7 interfaces connecting DoseMonitor/Nexodose with the facilities' Oracle Health/Cerner environment across Production and Test instances. Interested potential contractors must submit a capability statement, company details, UEI number, applicable GSA contract, product brochures with specifications, and an authorized service provider letter from the OEM. All prospective contractors must be registered in SAM.gov and complete electronic annual representations and certifications, with SDVOSBs and VOSBs verified in the SBA Small Business Search. Written capability submissions are due by October 22, 2026, at 11:00 AM Central Time to Contracting Officer Betty Flores at [email protected]. The anticipated performance period consists of a base year from February 1, 2027, to January 31, 2028, plus one option year through January 31, 2029. Work will occur primarily remotely, with potential on-site support required at designated VA facilities in Kansas, Missouri, and Illinois. Contractor staff requiring network access must pass background investigations and complete VA security and privacy training.
Official SAM.gov notice
- Solicitation number
- 36C25527Q0017
- Agency
- Department of Veterans Affairs
- Buying office
- 255-Network Contract Office 15 (36C255)
- Notice type
- Sources Sought
- Responses due
- Oct 29, 2026, 12:00 PM ET
- Posted on SAM.gov
- Oct 19, 2026
- NAICS
- 541519 · Other Computer Related Services
- Place of performance
- Kansas City, MO
- Contracting contact
- Betty Flores
veronica.flores@va.gov
Read the official notice description
This is a SOURCES SOUGHT announcement only. It is neither a solicitation announcement nor a request for proposal or quote and does not obligate the Government to award a contract. Responses to this Sources Sought must be in writing. The purpose of this Sources Sought Announcement is for market research, to make appropriate acquisition decisions, and to gain knowledge of potential qualified businesses capable of providing the following: DoseMonitor/Nexodose Management for Kansas and Missouri VA Medical Facilities *** See Statement of Work below for details *** If this is within your capability, please respond with the information below: Company Name Address Point of Contact Phone, Fax, and Email UEI number GSA Contract (as applicable) Capability Statement that clearly and convincingly identifies your ability to fulfill this requirement. Brochures of product being offered to include specifications. Authorized service provider letter from OEM Interested firms are reminded that in accordance with FAR 4.203, prospective contractors shall complete electronic annual representations and certifications to be considered for award. In addition, FAR 4.203 states that prospective contractors shall be registered in the System for Award Management (www.SAM.gov) database. All Service-Disabled Veteran Owned Small Businesses (SDVOSB) and Veteran Owned Small Businesses (VOSB) shall be verified in SBA at Small Business Search . Point of Contact for this Sources Sought is: [email protected] Department of Veterans Affairs Network Contracting Office -15 3450 S. 4th Street Trafficway Leavenworth, KS. 66048 STATEMENT OF WORK (SOW) Radiation Dose Tracking Software Maintenance, Support, and Bi-Directional HL7 Interface Services (DoseMonitor/Nexodose) Department of Veterans Affairs Veterans Integrated Service Network (Legacy VISN) Kansas and Missouri VA Medical Facilities: Period of Performance (Base Year): 02/01/2027 – 01/31/2028 Period of Performance (Option Year 1): 02/01/2028 – 01/31/2029 1. BACKGROUND Kansas and Missouri VA Medical Facilities currently utilizes the DoseMonitor (Nexodose) radiation dose tracking and monitoring software platform to capture, track, and report patient radiation exposure associated with diagnostic and interventional imaging procedures. This system supports clinical safety, regulatory compliance (e.g., accreditation and federal radiation safety reporting), and quality assurance functions for Radiology and related imaging services at the facility identified above. The facility's DoseMonitor/Nexodose environment will require that it interfaces upon conversion, bidirectionally with the site's electronic health record (Oracle Health/Cerner) via HL7 messaging to support orders and results exchange, and includes an outbound API/HL7 feed for downstream data consumption. Continued annual maintenance and support (M&S) is required to sustain system availability, vendor-supplied upgrades/updates, and interface reliability across the Production and Test environments. 2. PURPOSE / SCOPE The Contractor shall provide annual software maintenance and support for the DoseMonitor/Nexodose platform, the outbound API/HL7 interface, and the bi-directional HL7 interfaces between DoseMonitor/Nexodose and the site's Cerner environment (both Production and Test instances), and shall perform one-time installation/configuration of the bi-directional Cerner HL7 interfaces in both the Production and Test environments, in accordance with the Contract Line Item Numbers (CLINs) identified in Section 4 below. This SOW covers a base period of performance and one (1) option period, as detailed in Section 5. 3. APPLICABLE DOCUMENTS The Contractor shall perform all work in accordance with: VA Handbook 6500 and applicable VA Information Security requirements HIPAA Privacy and Security Rules (45 CFR Parts 160, 164) Health Level Seven (HL7) v2.x messaging standards, as applicable to the interfaces described herein Section 508 of the Rehabilitation Act (accessibility standards), where applicable to any software deliverables VA Directive 6102, VA Enterprise Architecture, and applicable VISN / facility local IT and Biomedical Engineering policies Manufacturer/vendor technical specifications for DoseMonitor/Nexodose 4. CONTRACT LINE ITEMS (CLINs) AND TASK REQUIREMENTS CLIN Description Qty/UOM DM-10-KAN-BY-AM&S — DoseMonitor/Nexodose Annual Maintenance & Support 1 EA DM-10-KAN-BY-OB — Outbound API/HL7 Annual Maintenance & Support 2 EA DM-10-KAN-BY-CERNER PRO — Bi-Directional (Orders/Results) HL7 Interface to Cerner, PRODUCTION 1 EA DM-10-KAN-BY-CERN-HL7-P — Bi-Directional Interface, Cerner PRODUCTION, Annual M&S (includes all upgrades/updates) 1 EA DM-10-KAN-BY-CERNER TEST — Bi-Directional (Orders/Results) HL7 Interface to Cerner, TEST 1 EA DM-10-KAN-BY-CERN-HL7-T — Bi-Directional Interface, Cerner TEST, Annual M&S (includes all upgrades/updates) 1 EA Base Period Total: 4.1 CLIN 0001 — DoseMonitor/Nexodose Annual Maintenance & Support The Contractor shall provide annual software maintenance and technical support for the DoseMonitor/Nexodose application, to include: Access to a technical support/help desk during standard business hours (minimum 8:00 AM – 5:00 PM local facility time, Monday–Friday, excluding federal holidays), with a defined escalation path for critical (system-down) issues. All vendor-issued software updates, patches, and version upgrades released during the period of performance, at no additional cost. Remote diagnostic and troubleshooting support for software defects, performance issues, and configuration errors. Proactive notification of known issues, security patches, and end-of-life/end-of-support milestones affecting the software. Software license renewal/maintenance to ensure continued authorized use of the application for the period of performance. 4.2 CLIN 0002 — Outbound API/HL7 Annual Maintenance & Support The Contractor shall provide annual maintenance and support for the outbound API/HL7 interface(s) used to export dose-tracking data from DoseMonitor/Nexodose to downstream consuming systems, to include: Monitoring and support of outbound message transmission to ensure data integrity and timely delivery. Troubleshooting and remediation of interface errors, message failures, or mapping issues. Support for any vendor-side configuration changes required due to upgrades to the DoseMonitor/Nexodose platform. Documentation of the outbound interface specification, updated as changes occur. 4.3 CLIN 0003 — Bi-Directional HL7 Interface to Cerner, PRODUCTION (One-Time Installation) The Contractor shall design, configure, install, and validate a bi-directional HL7 interface between DoseMonitor/Nexodose and the facility's Cerner Production environment to support orders and results exchange, to include: Interface build and configuration in coordination with facility Biomedical Engineering, Radiology, and Health Informatics/IT staff. HL7 message mapping (e.g., ORM/ORU or applicable message types) between DoseMonitor/Nexodose and Cerner. End-to-end interface testing and validation in the Production environment prior to go-live, including a documented test plan and results. Coordination of a go-live/cutover date with facility stakeholders and the VA Interface Team. Delivery of as-built interface documentation, including message specifications and data mapping. 4.4 CLIN 0004 — Bi-Directional Interface, Cerner PRODUCTION, Annual Maintenance & Support Following successful installation under CLIN 0003, the Contractor shall provide annual maintenance and support for the Production bi-directional HL7 interface, to include: All upgrades and updates to the interface engine/configuration required to maintain compatibility with DoseMonitor/Nexodose and Cerner throughout the period of performance. Ongoing interface monitoring support and troubleshooting of message failures or data discrepancies. Support for interface re-validation following any Cerner or DoseMonitor/Nexodose upgrade that affects message exchange. 4.5 CLIN 0005 — Bi-Directional HL7 Interface to Cerner, TEST (One-Time Installation) The Contractor shall design, configure, install, and validate a bi-directional HL7 interface between DoseMonitor/Nexodose and the facility's Cerner Test/non-production environment, mirroring the scope described in Section 4.3, to support pre-production testing, patch validation, and upgrade regression testing without impact to the Production environment. 4.6 CLIN 0006 — Bi-Directional Interface, Cerner TEST, Annual Maintenance & Support Following successful installation under CLIN 0005, the Contractor shall provide annual maintenance and support for the Test bi-directional HL7 interface, mirroring the scope described in Section 4.4, to ensure the Test environment remains a reliable, up-to-date proving ground for changes prior to Production deployment. 5. PERIOD OF PERFORMANCE Period Dates Base Period 02/01/2027 – 01/31/2028 Option Period 1 02/01/2028 – 01/31/2029 6. PLACE OF PERFORMANCE Work under this SOW shall be performed primarily remotely from the Contractor's facility. On-site support at Legacy VISN sites include: Eastern Kansas: Topeka, KS, Eastern Kansas: Leavenworth, KS, Wichita, KS, Kansas City, MO, St. Louis, MO, Columbia, MO, Poplar Bluff, MO, Marion, IL may be required for initial interface installation, go-live support, or troubleshooting that cannot be resolved remotely, at no additional cost to the Government unless otherwise negotiated and documented in the contract. 7. GOVERNMENT FURNISHED INFORMATION / EQUIPMENT The Government will provide: Remote access credentials/VPN access as required for Contractor support staff, subject to VA background investigation and PIV/security requirements (see Section 9). Access to relevant technical points of contact within facility Biomedical Engineering, Health Informatics, and IT/OI&T staff. Existing system documentation, network diagrams, and interface specifications as available. 8. DELIVERABLES Deliverable Due Date Interface Test Plan (Production & Test) Prior to installation/go-live Interface Validation/Test Results Report Upon completion of interface testing, prior to go-live As-Built Interface Documentation Within 10 business days of go-live Monthly/Quarterly Maintenance Status Report (if required by COR) Per COR-specified cadence Annual Software License/Maintenance Renewal Confirmation Prior to expiration of current M&S term 9. SECURITY AND PRIVACY REQUIREMENTS The Contractor shall comply with all applicable VA information security and privacy requirements, including but not limited to: Execution of a Business Associate Agreement (BAA) if the Contractor will have access to Protected Health Information (PHI). Compliance with VA Handbook 6500 for information security. Completion of VA Privacy and Information Security Awareness training and signed Rules of Behavior by all Contractor personnel prior to system access. Any remote access to VA systems shall be through VA-approved, encrypted connections only. No PHI or PII shall be removed from VA systems or transmitted outside of VA-approved channels. Contractor personnel requiring recurring access to VA networks/systems shall undergo background investigation (e.g., NACI or higher, as determined by the VA Personnel Security office) commensurate with position sensitivity. 10. QUALITY ASSURANCE / ACCEPTANCE CRITERIA All one-time interface installations (CLINs 0003 and 0005) shall be deemed complete upon successful bi-directional message exchange testing, validated jointly by the Contractor and designated facility/VISN 15 technical staff, and formal written acceptance by the Contracting Officer's Representative (COR). Annual maintenance and support services (CLINs 0001, 0002, 0004, 0006) shall be monitored via a Quality Assurance Surveillance Plan (QASP), to be maintained by the COR, measuring support responsiveness, resolution timeliness, and system uptime/availability.
Source: SAM.gov contract opportunities data (U.S. federal public data).
Incumbent
No incumbent history found for this requirement. The notice does not cite a current contract, and no earlier award from this buying office matches it.
Market context
Awards in the same category (Other Computer Related Services). This is not this requirement's award history.
Recent similar awards: Department of Veterans Affairs, NAICS 541519, performed in MO
| Vendor and award | Value | Ends |
|---|---|---|
| ALVAREZ LLC36C25526F0013 · INTERACTIVE TV & DIGITAL SIGNAGE SERVICES | $575.0K | Oct 31, 2030 |
| REGENCY CONSULTING INC36C25524C0015 · REJIS CRIMANAL BACKGROUND CHECK | $25,876 | Jan 31, 2028 |
| PROAIM AMERICAS, LLC.36C10B26P0025 · ZEISS FORUM ORACLE HEALTH SOFTWARE LICENSES AND INTEGRATION SERVICES FOR VISN 15 | $122.0K | Jan 30, 2028 |
| ALVAREZ LLC36C25526P0012 · VOCERA SUPPORT SERVICES | $1.1M | Nov 30, 2027 |
| ALVAREZ LLC36C10B26F0349 · VOCERA SOFTWARE LICENSES AND HARDWARE SUPPORT SERVICES IN SUPPORT OF VETERANS HEALTH ADMIN | $628.0K | Sep 29, 2027 |
Top vendors in this category: Department of Veterans Affairs, NAICS 541519, since Oct 1, 2024
4,116 contract awards in this NAICS over the period.
- 1. V3GATE, LLC$1.0B
- 2. THUNDERCAT TECHNOLOGY, LLC$712.0M
- 3. FOUR POINTS TECHNOLOGY, L.L.C.$534.1M
- 4. MINBURN TECHNOLOGY GROUP, LLC$330.1M
- 5. METGREEN SOLUTIONS INC$302.4M
Source: USAspending.gov federal award data (U.S. federal public data). A contract is called the incumbent only when the notice or its documents cite it by number.
Verify important details
Document checkConfirm submission instructions and amendments with the issuing agency before responding.
Personalized fit score
Sign up free to see how well this opportunity fits your company — based on your saved profile.
Sign up to see your fit score