578-19-026: Installation of Hines Gate Control at the Hines VA Hospital in Hines, IL

Federal · Department of Veterans AffairsDue Monday, October 5, 2026
Client
Department of Veterans Affairs
RFP Number
—
Posted
10/1/2026
Category
US Federal
Budget
—
NAICS
238210
Set-aside
small business firms to determine if a set-aside is appropriate. Responses to this Sources Sought announcement will be used by the Government to make appropriate acquisition decisions. Proposals are NOT being requested or accepted at this time. The Depar
Contact
Kristi Kluck

Description

AI Generated

The Department of Veterans Affairs, Great Lakes Acquisition Center, seeks capabilities and qualification information to determine if a set-aside is appropriate for the Hines Gate Control System project. The required scope includes furnishing all labor, materials, equipment, tools, and supervision to upgrade power, communications, and security infrastructure, replace non-compliant perimeter fencing, and modernize or close various gates across the campus. The VA requests letters of interest from small businesses, including SDVOSB, VOSB, WOSB, 8(a), HUBZone, and general small or large businesses under NAICS code 238210. Interested sources must submit a single PDF or Word document of up to six pages via email to [email protected] by October 5, 2026, at 12:00 PM Central Time. The submission must include company details, business status, primary business nature, bonding capacity letters, and two project examples of similar scope, complexity, and magnitude. This notice serves as market research only, and proposals are not currently requested or accepted. The estimated construction magnitude exceeds $10,000,000, and the period of performance will not exceed 450 calendar days.

Official SAM.gov notice

Solicitation number
36C25227B0004
Agency
Department of Veterans Affairs
Buying office
252-Network Contract Office 12 (36C252)
Notice type
Sources Sought
Responses due
Oct 5, 2026, 1:00 PM ET
Posted on SAM.gov
Sep 28, 2026
NAICS
238210 · Electrical Contractors and Other Wiring Installation Contractors
Product/service code
Y1PZ
Place of performance
60141-5000
Contracting contact
Kristi Kluck, Contracting Officer
[email protected]
414-844-4879
Read the official notice description

THIS IS A SOURCES SOUGHT NOTICE ONLY Solicitation: 36C25227B0004 Project: 578-19-026 Hines Gate Control System Place of Performance: Edward Hines, Jr. VA Hospital (EHVAH) 5000 South 5th Avenue Hines, IL 60141-5000 PART 1 - General Description: The purpose of this notice is to obtain information on the interests, capabilities, and qualifications of multiple types of small business firms to determine if a set-aside is appropriate. Responses to this Sources Sought announcement will be used by the Government to make appropriate acquisition decisions. Proposals are NOT being requested or accepted at this time. The Department of Veterans Affairs, Great Lakes Acquisition Center, requests a letter of interest from the following types of specialized construction small businesses firms interested in performing construction work at the Edward Hines, Jr. VA Hospital: Service-Disabled Veteran Owned Small Businesses (SDVOSB), Veteran Owned Small Businesses (VOSB), Women Owned Small Businesses (WOSB), 8(a) Businesses, HUBZone Businesses, and Small Businesses (SB) Large Business This project is classified under NAICS Code: 238210 - Electrical Contractors and Other Wiring Installation Contractors with a small-business size limit of $19.0 Million and PSC Y1PZ (Product Service Code Construction Other Non-Building Facilities) In accordance with VAAR 852.219-75(a)(iii) Special trade construction contractors, should this acquisition be procured as an SDVOSB or VOSB - [ ] The contractor will not pay more than 75% of the amount paid by the government to it to firms that are not certified SDVOSBs listed in the SBA certification database as set forth in 852.219-73 or certified VOSBs listed in the SBA certification database as set forth in 852.219-74. Any work that a similarly situated certified SDBOSB/VOSB subcontractor further subcontracts will count towards the 75% subcontract amount that cannot be exceeded. Costs of materials are excluded and not considered to be subcontracted. https://www.va.gov/oal/library/vaar/vaar852.asp#85221975 The magnitude of construction for this work is more than $10,000,000. The period of performance shall not exceed 450 calendar days. PART 2 - SCOPE OF WORK OVERVIEW: The existing gate system and perimeter fencing at the Hines VA campus does not have video surveillance, card reader access, pedestrian access gates, remote gate control and in some locations damaged fencing or missing sections. Most of the existing gates need to be closed manually and do not have mechanical drives for closure. The primary objectives of this contract are to furnish all labor, materials, equipment, tools, and qualified supervision necessary to: 1) Task 1: Install upgraded and code compliant power and communications infrastructure to support security systems and gate operations for Building 205 and Gates 2, 3, and 4 and replace any non-compliant perimeter fencing along 5th Avenue. 2) Task 2: Modernize and secure campus primary entrance (Gate 1), by implementing power, communications, security, fence, and gate control improvements at Gate 1 in the northeast sector and replace any non-compliant perimeter fencing surrounding Gate 1. 3) Task 3: Remove and permanently close Gate 13 and replace all non-compliant perimeter fencing along the Roosevelt Road fence line 4) Task 4, enhance northwest perimeter security by upgrading Gates 11 and 12, integrating required systems, and replacing non-compliant fencing along southbound 9th Avenue to Gate 10. 5) Task 5, strengthen the west perimeter by improving fencing and modernizing Gate 10 to support controlled access, and replace non-compliant fencing from Gate 10 to the southern boundary. 6) Task 6, upgrade Gate 7 to improve access control and security along the central southeastern perimeter and replace non-compliant fencing to the north and east of Gate 7. 7) Task 7, improve perimeter security near Building 37 by upgrading Gate 14 and associated communications infrastructure, and replace non-compliant fencing to the north and east of the building. 8) Task 8, enhance the southeastern perimeter by renovating Gates 8 and 9 and integrating required electrical, communications, and security upgrades, and replace non-compliant fencing along 1st Avenue. 9) Task 9, reconstruct the southern perimeter fence line to meet VA security standards and replace all non-compliant fencing. PART 3 - Interested sources shall submit the following: Company name, address, point of contact, phone number, SAM OID number, and business status. Indicate the primary nature of your business, any teaming agreements or arrangements, self- performance, and intentions of subcontracting program, including set-asides. Documentation relating to capability of performance. Provide two (2) examples of projects similar in scope, complexity, and cost magnitude of project description above. Letter from the surety regarding the maximum bonding capability for a single contract action as well as the total aggregate bonding capacity. Total submittal shall be no longer than (6) six pages in one .pdf file or word document. Responses are required to be sent via email to [email protected] no later than Monday, October 5, 2026, CST. THIS IS NOT A REQUEST FOR PROPOSALS. It is a market research tool being utilized to determine the availability of potential qualified contractors before determining the method of acquisition. In addition, this Sources Sought is not to be construed as a commitment by the government, nor will the government pay for any information solicited or delivered.

Source: SAM.gov contract opportunities data (U.S. federal public data).

Incumbent

Likely prior awards for this requirement

Likely match

Awarded by the same buying office (36C252) with descriptions matching "hines gate" or "control". The notice does not name its current contract, so confirm before relying on it.

Vendor and awardValueEnds
CDS SERVICES INC36C25226P0008 · PEST CONTROL SERVICES FOR THE TOMAH VA HOSPITAL IN TOMAH WI$26,004Sep 30, 2030
GUIDON MES JV, LLC36C25223N0321 · 578-19-026 HINES GATE CONTROL SYSTEM DESIGN$1.1MMar 21, 2026

Market context

Awards in the same category (Electrical Contractors and Other Wiring Installation Contractors). This is not this requirement's award history.

Recent similar awards: Department of Veterans Affairs, NAICS 238210

Vendor and awardValueEnds
KAR CONTRACTING LLC36C24526C0059 · UPGRADE ELECTRICAL INFRASTRUCTURE 581-22-102 FAR 52.222-90. FPDS DESCRIPTION MUST ALSO INC$13.0MJul 13, 2031
N-OVATION TECHNOLOGY GROUP LLC36C25226P0151 · ANNUAL MAINTENANCE OF SATELLITE TV SYSTEM FOR DANVILLE VAMC$57,600Jan 31, 2031
PAVION CORP.36C24126P0103 · RAULAND RESPONDER BEDFORD MA VAMC$70,940Dec 31, 2030
PREFERRED COMMERCIAL CONTRACTING, INC.36C26326C0041 · 656-22-341, CONDUCT SUBSTATION UPGRADE$3.5MNov 15, 2028
DC SERVICES CNY, LLC36C24225C0093 · REPLACE 5MV TRANSFORMER$419.3KSep 18, 2028

Top vendors in this category: Department of Veterans Affairs, NAICS 238210, since Oct 1, 2024

619 contract awards in this NAICS over the period.

  1. 1. J & J MECHANICAL AND CONSTRUCTION GROUP LLC$19.2M
  2. 2. SKYTEK LLC$18.6M
  3. 3. MGI, INC.$13.5M
  4. 4. KAR CONTRACTING LLC$13.0M
  5. 5. FORUS CONTRACTING, INC.$10.6M

Source: USAspending.gov federal award data (U.S. federal public data). A contract is called the incumbent only when the notice or its documents cite it by number.

Source and verification

Original source

Craxy AI summarizes this opportunity from the original listing and available solicitation documents. Confirm submission instructions and amendments with the issuing source before responding.

1 cached source fileDocuments checked

Personalized fit score

Sign up free to see how well this opportunity fits your company — based on your saved profile.

Sign up to see your fit score