Nurse Call Systems Maintenance
- Client
- Department of Veterans Affairs
- RFP Number
- —
- Posted
- 10/10/2026
- Category
- Software, System and Application
- Budget
- —
- NAICS
- 541513
- Set-aside
- —
- Contact
- Rosangela Pereira
Description
AI GeneratedThe Department of Veterans Affairs intends to enter into a sole source contract with SIGNET Electronic Systems, LLC for nurse call systems maintenance at the Providence VA Medical Center. The scope requires preventative and corrective maintenance, next business day service, biannual functional assessments, and electronic service reports within 24 hours of work completion. The contractor must also upgrade specific Responder 4 systems to Responder 5K and add nurse call components to designated rooms during the base year. To be eligible, contractors must be located within 60 miles of the Providence VA Medical Center and be factory authorized to supply, install, and service Rauland Responder 4, 4K, 5, and 5K systems with full warranty privileges. The contract period of performance consists of a one-year base period plus four one-year option periods. While this notice is not a formal solicitation, responsible sources may submit a written capability statement to Contract Specialist Rosangela Pereira at [email protected] by October 13, 2026, at 12:00 PM Eastern Time.
Official SAM.gov notice
- Solicitation number
- 36C24126Q0857
- Agency
- Department of Veterans Affairs
- Buying office
- 241-Network Contract Office 01 (36C241)
- Notice type
- Special Notice
- Responses due
- Oct 13, 2026, 12:00 PM ET
- Posted on SAM.gov
- Oct 8, 2026
- NAICS
- 541513
- Product/service code
- J065
- Contracting contact
- Rosangela Pereira, Contract Specialist
Rosangela.Pereira@va.gov
401-273-7100
Read the official notice description
The Department of Veterans Affairs, Networking Contracting Office (NCO 01) located in Providence, RI intends to enter into a sole source procurement, pursuant to the authority of FAR 6.302-1, with SIGNET Electronic Systems, LLC for the following requirement: Performance Work Statement Nurse Call Systems Maintenance Summary/Requirements: The contractor shall provide preventative and corrective maintenance on the nurse call systems installed at the Providence VA Medical Center in the following locations: Building 1/Area Responder Version ED Responder 4 OR/Clean Core/PACU Responder 4 Hemo/ICU Responder 5 3B Responder 5 4A Responder 5K 4B Responder 5 5B Responder 5 6A Responder 5 6B Responder 5 B-39 Responder 5 MRI Addition (In Construction) Responder 5 The scope of service provided is as follows: The contractor shall provide next business day service. Labor, mileage, and trip charges shall be included. The contractor shall perform a biannual functional assessment of each system outlined above and shall provide a report outlining the satisfactory/unsatisfactory test status of each system and end device. A follow-on plan with associated proposal for parts necessary to return the system to fully satisfactory condition shall be provided to the customer. Labor, mileage, and trip charges associated with the above outlined repairs will be included in the service contract. Base year will include the upgrade of the ED and OR/Clean Core/PACU Responder 4 systems to Responder 5K to allow the systems to be fully supported into the future. This process includes all labor, materials, programming and engineering by the contractor to satisfy this requirement. Base year will include the addition of nurse call components necessary to bring rooms 460, 469, and 485 into clinical compliance for nurse call. This process includes all labor, materials, programming and engineering by the contractor to satisfy this requirement. The contractor shall provide an electronic service report for all preventative and repair work whether scheduled service or call-in repair work within 24 hours of the completion of the work order. Qualifications of Contractors The contractor shall be within 60 miles of the Providence VA Medical Center. The contractor shall be factory authorized and entitled to supply, install, and service the Rauland Responder 4, 4K, 5, and 5K nurse call systems and have full factory warranty privileges. Place of Performance VAMC Providence 830 Chalkstone Avenue Providence, RI 02908 Period of Performance The contract period of performance is one-year base period plus four one-year option periods. The NAICS code for this requirement is 541513. SIGNET Electronic Systems, LLC is the only authorized Rauland Responder Nurse Call distributor that can supply, install, service, and has full warranty privileges in the New England region. SIGNET is authorized to supply, install, and service the Rauland Responder 4, 4K, 5, and 5K nurse call systems and have full factory warranty privileges. This notice of intent is not a solicitation nor is it a request for proposal. However, all responsible sources may submit a capability statement demonstrating the ability to provide the requested services, in writing by Tuesday, October 13, 2026 at 12PM EST. Responses should be sent to Rosangela Pereira at [email protected]. Information submitted in response to this notice will be used solely to determine whether competitive procedures could be used for this acquisition. A determination not to open the requirement to competition based upon responses to this notice is solely within the discretion of the Government.
Source: SAM.gov contract opportunities data (U.S. federal public data).
Verify important details
Document checkConfirm submission instructions and amendments with the issuing agency before responding.
Personalized fit score
Sign up free to see how well this opportunity fits your company — based on your saved profile.
Sign up to see your fit score