FreeFree RFPs on Craxy AI — no subscription required

Get one free complete proposal every month

Sign up free — Craxy AI reads the RFP, drafts every section, and matches your past work.

NRM A/E- 528A7-27-112 Fire Alarm Panel Upgrade RFI

Federal · Department of Veterans AffairsDue Tuesday, November 3, 2026
Client
Department of Veterans Affairs
Solicitation No.
36C24227Q0070
Posted
10/21/2026
Category
US Federal
Budget
—
NAICS
541330
Set-aside
—
Contact
Ryan Seburn

Description

AI Generated

The Department of Veterans Affairs seeks information on qualified Architect-Engineer firms to provide complete design and cost estimation services for upgrading the Edwards EST-3 fire alarm system at the Syracuse VA Medical Center. Scope includes upgrading control panels and remote annunciators, installing a fiber loop network and master control panel, expanding the addressable system, removing the fireman telephone system, developing a construction phasing plan, and providing construction period services. Work requires complete working drawings, specifications, detailed cost estimates, and compliance with NFPA 70, NFPA 72, NEC, and VA construction standards. All responsible Architect-Engineer sources under NAICS 541330 with a size standard of $25.5M may submit a capability statement. Prime firms must have a registered Fire Protection Engineer on staff to stamp all drawings. Interested parties must submit written inquiries and responses by email to [email protected] by 10:00 AM Eastern Time on November 3, 2026. The government will not accept phone calls or award a contract from this Request for Information.

Key solicitation details

AI-extracted from 36C24227Q0070.docx. Confirm against the original documents before bidding.

The Department of Veterans Affairs is issuing a Request for Information to identify qualified Architect-Engineer firms to provide design and cost estimation services for upgrading the fire alarm system at the Syracuse VA Medical Center. All responsible sources may submit a capability statement. This notice is for information only and does not constitute a commitment or solicitation for proposals.

Issued by
Department of Veterans Affairs
Response Date
11-03-2026 10:00 EASTERN TIME, NEW YORK, USA
Inquiries due
10:00 EST November 3rd, 2026
How to submit
email
Submission details
Send written responses and inquiries to Contract Specialist Ryan Seburn by email. Phone calls will not be accepted.
Place of performance
Syracuse VA Medical Center, 800 Irving Avenue, Syracuse, New York 13210, USA

Scope of work

  • Upgrade existing obsolete Edwards EST-3 fire alarm control panels and remote annunciators
  • Install a new fiber loop network connecting all panels and a new master control panel
  • Expand the addressable system to additional campus buildings
  • Remove the existing fireman telephone system
  • Develop a phasing plan that maintains continuous fire alarm protection throughout construction
  • Prepare complete working drawings, specifications, and detailed cost estimates
  • Provide construction period services

Minimum qualifications

  • Must be a qualified Architect-Engineer (A/E) firm
  • Prime firm must have a Fire Protection Engineer (FPE) on staff - no exceptions
  • All drawings must be stamped by a registered Fire Protection Engineer (FPE)

Documents to include with the bid

  • Capability statement

Official SAM.gov notice

Solicitation number
36C24227Q0070
Agency
Department of Veterans Affairs
Buying office
242-Network Contract Office 02 (36C242)
Notice type
Sources Sought
Responses due
Nov 3, 2026, 10:00 AM ET
Posted on SAM.gov
Oct 20, 2026
NAICS
541330 · Engineering Services
Product/service code
C1DA
Place of performance
Syracuse, NY, 13210
Contracting contact
Ryan Seburn, Contract Specialist
Ryan.Seburn@va.gov
(518)626-6138
Read the official notice description

This is a "REQUEST FOR INFORMATION" only. This is NOT a solicitation for proposals, proposal abstracts, or quotations. The purpose of this notice is to obtain information regarding the availability and capability of qualified sources to perform a potential requirement. This notice does not constitute a commitment by the Government, and no contract will be awarded from this notice. Responses to this Sources Sought notice must be in writing. The Department of Veterans Affairs is seeking qualified Architect-Engineer (A/E) firms to provide complete design and cost estimation services to upgrade the existing obsolete Edwards EST-3 fire alarm system (Project No. 528A7-24-112) at the Syracuse VA Medical Center located at 800 Irving Avenue, Syracuse, NY 13210. Work includes upgrading the existing fire alarm control panels and remote annunciators, installing a new fiber loop network connecting all panels and a new master control panel, expanding the addressable system to additional campus buildings, removing the existing fireman telephone system, and developing a phasing plan that maintains continuous fire alarm protection throughout construction. The A/E shall prepare complete working drawings, specifications, and detailed cost estimates, and provide construction period services. All drawings must be stamped by a registered Fire Protection Engineer (FPE), and the prime firm must have an FPE on staff no exceptions. Design shall comply with the latest editions of NFPA 70, NFPA 72, and the NEC, as well as applicable VA construction standards and fire protection design criteria. The NAICS Code is 541330 Engineering Services", with a size standard of $25.5M. All responsible sources may submit a capability statement which shall be considered by the Syracuse VA Medical Center. Please send all inquiries to: [email protected] by 10:00 EST November 3rd, 2026. Phone calls will not be accepted.

Source: SAM.gov contract opportunities data (U.S. federal public data).

Incumbent

Likely prior awards for this requirement

Likely match

Awarded by the same buying office (36C242) with descriptions matching "fire alarm", performed in NY. The notice does not name its current contract, so confirm before relying on it.

Vendor and awardValueEnds
FELLENZER ENGINEERING LLP36C24224C0021 · FIRE ALARM REPLACEMENT DESIGN AT THE MONTROSE VAMC$269.6KSep 30, 2028
JOHNSON CONTROLS FIRE PROTECTION LP36C24226F0028 · FIRE ALARM MAINTENANCE, TESTING AND INSPECTIONS$359.8KOct 31, 2027
JOHNSON CONTROLS INC36C24224P0022 · BATH VAMC FIRE ALARM SERVICE AND MAINTENANCE$133.4KSep 30, 2027
VETERANS FIRE AND LIFE SAFETY CORPORATION36C24223P0021 · FIRE ALARM ANNUAL INSPECTION, TESTING, MAINTENANCE, AND MONITORING SERVICES EDWARDS GE EST$810.0KSep 30, 2027
HURTVET SUBCONTRACTING, INC.36C24226P0860 · FIRE ALARM SERVICES$297.8KAug 23, 2027

Market context

Awards in the same category (Engineering Services). This is not this requirement's award history.

Recent similar awards: Department of Veterans Affairs, NAICS 541330, performed in NY

Vendor and awardValueEnds
AE WORKS LTD36C24226C0086 · EO 14398$174.6KSep 30, 2031
WEST POINT ENGINEERS LLC36C24225C0105 · REPLACE ROOF BUILDING # 1 AT MANHATTAN$903.6KApr 8, 2031
SPECIALIZED ENGINEERING SOLUTIONS INC36C24226C0068 · REPLACE CHILLER 4, PROJECT 526-27-101-AE DESIGN AT THE JAMES J. PETERS DVA MEDICAL CENTER,$1.4MDec 30, 2030
FELLENZER ENGINEERING LLP36C24226C0031 · 620A4-22-103 ROOFS CP$148.3KSep 30, 2030
TOLAND MIZELL MOLNAR LLC36C24226C0005 · DESIGN REPLACE FLAT ROOFS$597.4KSep 30, 2030

Top vendors in this category: Department of Veterans Affairs, NAICS 541330, since Oct 1, 2024

3,049 contract awards in this NAICS over the period.

  1. 1. AMERESCO INC$311.2M
  2. 2. RWE CLEAN ENERGY SOLUTIONS, INC.$70.6M
  3. 3. TLS-CES SERVICES I, LLC$44.5M
  4. 4. ANDERSON ENGINEERING OF MINNESOTA, LLC$39.0M
  5. 5. NORESCO, LLC$36.6M

Source: USAspending.gov federal award data (U.S. federal public data). A contract is called the incumbent only when the notice or its documents cite it by number.

Verify important details

Document check

Confirm submission instructions and amendments with the issuing agency before responding.

1 available fileDocuments checked

Personalized fit score

Sign up free to see how well this opportunity fits your company — based on your saved profile.

Sign up to see your fit score